Failed Electrical Inspection: What Happens Next and How to Pass the Second Time

Failed electrical inspection? What the correction notice means, the most common reasons work fails, who pays for the fix, and how to pass the reinspection.

A failed electrical inspection feels like a verdict on the whole job. It rarely is. Most failures come down to a short list of fixable items, and the inspector has already told you what they are. This guide explains what a failed electrical inspection actually means, the most common reasons work fails, who pays for the fix, and how to make sure the second visit is the last one.

Want a first idea of what the corrections will cost? Answer a few questions in our electrical repair cost estimator.

Failed electrical inspection: what it actually means

When you pull a permit, the work is checked by the electrical inspector of your city or county, the authority having jurisdiction. A failed inspection means the work does not yet meet the code as your jurisdiction adopted it. It is not a fine, and it does not automatically mean your house is dangerous. It means the job is not finished yet.

What changes in practice depends on the job. On a remodel, you usually cannot close the walls or move on to the next inspection until the corrections pass. On a new service or a service upgrade, the utility will not connect the power until the inspection is signed off. If you are not sure which work needs a permit in the first place, read electrical permit: when do you need one?

The correction notice: how to read it

After a failed visit, the inspector leaves a list of corrections. Depending on the jurisdiction it is called a correction notice, a correction list, or simply a failed inspection result in the online permit portal. Each item describes what is wrong, and often where, and sometimes cites the code section behind it.

Read it item by item, and do not guess. If a line is unclear, call the inspector and ask what exactly he or she wants to see at the next visit. Most inspectors are glad to explain, because a clear answer saves them a third trip. A question asked calmly on the phone gets you much further than a discussion in the hallway during the inspection.

Why electrical work fails inspection

Almost nobody fails because of something exotic. These are the items that come back over and over:

  1. Missing GFCI or AFCI protection in a location where the code requires it. Our guide to where the NEC wants GFCI protection lists the rooms.
  2. Overfilled boxes. Too many conductors, clamps or devices for the size of the box.
  3. Cables not secured or not protected, such as cable that is not stapled near the box, or a hole bored too close to the edge of a stud without a nail plate.
  4. A breaker too large for the wire it protects.
  5. Grounding and bonding that is missing, loose or connected in the wrong place.
  6. Two wires under one terminal. See why inspectors flag double tapped breakers.
  7. Labels and directories, such as a panel directory that says only “lights”, or a GFCI outlet on an ungrounded circuit without its required label.
  8. A panel that is hard to reach, with shelves or a freezer blocking the working space in front of it, or a panel placed in a clothes closet or a bathroom, where the code does not allow it.
  9. Junction boxes that are no longer accessible, plastered over, tiled in or hidden behind drywall or a fixed cabinet. Every splice has to stay reachable without tearing anything open.
  10. Missing cover plates or receptacles that are not tamper resistant.
  11. Work covered too early, for example insulation or drywall installed before the rough inspection passed.

Most of these also show up in our list of the 22 findings in every electrical inspection report, with a rough cost for each one.

Failed electrical inspection: who pays for the fix?

A contractor pulled the permit. Correcting his own work is normally part of the job he was paid for. Check your contract for how reinspection fees are handled, because many jurisdictions charge one for each extra visit.

You pulled a homeowner permit. Then the corrections are yours, either to do yourself where your jurisdiction allows it, or to hand to a licensed electrician.

The inspector found an older problem. Sometimes the notice includes a defect that was not part of the job, for example in the panel the new circuit connects to. That is extra work, and it is worth discussing with your electrician before anyone starts, so there is no surprise on the bill.

The inspector is human too

In fifteen years of inspecting electrical installations, I learned that an inspection is a snapshot made by a person. An inspector often has many stops in one day. He walks into a house with children running around, an owner standing next to him and sometimes a contractor who wants to argue about every item. An inspector who is confident in his work does not let that influence him, but it takes experience and calm to miss nothing under those conditions.

That works in both directions. A pass is not a guarantee that nothing is wrong, and a fail is not a personal attack. An electrician who spends a whole day in your house will often find more than an inspector can see in a short visit, so when the corrections are made, it is worth having the rest of the panel looked at too.

We are all human, and people make mistakes. We learn from them when we give each other room.

How to pass the reinspection

  1. Fix every item on the list, not most of them. One open item means another failed visit.
  2. Look for the same mistake elsewhere. If one box was overfilled, check the others. Inspectors notice when only the box on the list was corrected.
  3. Take photos of each correction, especially anything that will be covered later.
  4. Schedule the reinspection the way your jurisdiction asks, keep the permit card and the correction notice on site, and make sure the panel and the corrected areas are easy to reach.
  5. Be there, or have your electrician there, so any question can be answered on the spot.
  6. Get the sign off in writing and keep it with your house documents.

Adding circuits as part of the corrections? Check whether your panel can carry them with the circuit load calculator.

Failed electrical inspection when buying or selling a house

Two different inspections get mixed up here. A home inspection is a private inspection the buyer orders. The home inspector writes a report, but nothing legally passes or fails. A permit inspection is done by the city or county, and its result is part of the public permit record.

That record matters at sale. A permit with a failed final inspection stays open, and buyers, their agents and their lenders can find it. If you are planning to sell, close open permits before you list the house. It is far easier to finish a correction list now than to negotiate about it during escrow.

Failed electrical inspection: the short version

A failed electrical inspection means the work is not finished yet, not that it is a disaster. Read the correction notice line by line, ask the inspector when something is unclear, fix every item, and look for the same mistake elsewhere. Settle who pays before the work starts, close the permit before you sell, and remember that the inspector, like you, is only human.

This article is general information about residential electrical systems, not a code ruling for your home. Code adoption varies by state and city, and your local electrical inspector has the final word. Have any work done by a licensed electrician.

Rahmouni, author of FIXMIRO

Who writes this

FIXMIRO is written by Rahmouni, an industrial engineer who spent fifteen years inspecting electrical installations and seven inspecting gas. What you read here is what he used to explain to homeowners while standing at their panel, written out properly.

Use the free calculators