A generator interlock kit and a transfer switch do the same basic job: they let you run your home on a portable generator during an outage without sending power back into the utility lines. They do it in different ways, at different costs, and with different trade offs in daily use. This guide explains both, the one method you should never use, and the details that decide whether your setup passes inspection.
Why you cannot just plug a generator into an outlet
Some people connect a generator to the house with a cord that has a plug on both ends, often into the dryer receptacle. Electricians call it a suicide cord, and for good reason. The bare prongs on the generator end carry full voltage when the other end is plugged in. And if the main breaker is still on, the generator feeds back through your service into the utility transformer, which steps the voltage up to thousands of volts on the lines outside. A line worker repairing the outage can be killed by power from your garage.
The NEC requires that a backup source and the utility can never be connected at the same time. Both an interlock kit and a transfer switch meet that rule. A cord with two plugs does not.
How a generator interlock kit works
A generator interlock kit is a metal plate that mounts on the front of your main panel. It slides between the main breaker and a two pole breaker used for the generator. When the main breaker is on, the plate blocks the generator breaker. To turn the generator breaker on, you first have to switch the main breaker off. The two can never be on together.
A complete installation has four parts:
- The interlock plate, made and listed for your specific panel brand and model.
- A generator breaker, usually in the top position next to the main, and held in place with a retaining clip because it is fed backward.
- A power inlet box on the outside wall, where the generator cord plugs in.
- A generator cord sized for the inlet, for example a 30 amp cord for a 30 amp inlet.
With the main breaker off and the generator breaker on, the whole panel is live from the generator. You then decide which circuits to use by switching individual breakers on and off.
How a transfer switch works
A transfer switch is a separate piece of equipment that moves a load from utility power to generator power. There are two kinds for homes.
A manual transfer switch is a small panel mounted next to the main panel. A set of selected circuits, often six to ten, is rewired through it. Each circuit has its own switch with a line position and a generator position. Only those prewired circuits can run on the generator.
An automatic transfer switch senses when utility power fails, starts the generator and moves the load over on its own. It is used with a permanently installed standby generator, not with a portable one you roll out of the garage. It is the most comfortable option and by far the most expensive.
Generator interlock kit versus transfer switch: the differences
Cost. An interlock kit is usually the cheapest legal option, because the hardware is simple and no circuits need to be rewired. A manual transfer switch costs more in parts and labor. An automatic transfer switch with a standby generator is a much larger project.
Flexibility. With an interlock kit, every circuit in the panel is available. In a summer outage you can run the refrigerator and a window air conditioner; in winter, the furnace and the well pump. A manual transfer switch only gives you the circuits you chose on the day it was installed.
Ease of use. Here the transfer switch wins. With an interlock kit, you are the load manager: you have to switch off everything you do not need, or the generator will overload. A manual transfer switch limits the load by design, and an automatic one does everything for you.
Panel compatibility. An interlock kit only works if a listed kit exists for your panel and the generator breaker can sit in the right position. On an old or obsolete panel, that is often not the case. A transfer switch works next to almost any panel.
Sizing the generator and choosing circuits
Whichever method you choose, the generator has to carry what you switch on, including the starting surge of motors in a refrigerator, a well pump or an air conditioner. Make a short list of the circuits you really need in an outage and add up their load before you buy a generator or pick circuits for a transfer switch.
Add up the circuits you want to keep running with the circuit load calculator.
If you would rather have silent backup without fuel, a home battery is the alternative. You can estimate how long a battery would carry the same circuits with the battery runtime calculator.
Details that decide whether it passes inspection
- A listed interlock for your exact panel. A homemade bracket or a kit made for another brand is not acceptable.
- The generator breaker secured. A breaker fed from the generator side must be held in place by a clip or screw, so it cannot be pulled out while live.
- Breaker, inlet and cord that match. The generator breaker is not larger than the rating of the inlet and the wire behind it.
- The neutral handled correctly. Many portable generators have the neutral bonded to the frame. With an interlock kit or a transfer switch that does not switch the neutral, the neutral is already bonded in your main panel, and the generator bond creates a second connection. The manufacturer of the generator or the transfer equipment explains how to set this up; ask your electrician to check it.
- Labels. The panel should say that a generator is connected and how to switch over.
- A permit. Most cities and counties require one, and some utilities want to know about the connection.
Several of these points also show up on our list of the 22 findings in almost every electrical inspection report.
If you have solar panels
A grid tied solar system shuts down in an outage, and it should stay off while the generator runs. With an interlock kit the whole panel is on generator power, including the solar breaker, and an inverter that sees generator voltage may try to start feeding. Switch the solar breaker off before you start the generator, and ask your solar installer how the system should be handled. Our article on whether you can turn off your solar panels explains what shuts down automatically and what does not.
Carbon monoxide: the risk outside the panel
Most generator deaths are not electrical. They come from carbon monoxide. Run a portable generator outside only, far from doors, windows and vents, never in a garage, not even with the door open. Put a carbon monoxide alarm on every floor of the house.
Generator interlock kit or transfer switch: which one to choose
Choose a generator interlock kit if a listed kit exists for your panel, you want the lowest cost, and you are comfortable switching breakers yourself during an outage. Choose a manual transfer switch if other people in the house will run the generator, or if your panel has no interlock option. Choose an automatic transfer switch with a standby generator if outages are frequent or long where you live, or if someone in the house depends on power for medical equipment.
All three are safe when they are installed correctly by a licensed electrician. The cord with two plugs is never safe.
This article is general information about residential electrical systems, not a code ruling for your home. Code adoption varies by state and city, and your local electrical inspector has the final word. Have any work done by a licensed electrician.